紧凑型移动电气实验室 ETL-8

供应商代码 107585

0.0
评价产品

0 评论

价格 按需价格

描述

Van-based cable test and fault location system ETL-8 is used for testing cable insulation and locating cable faults using a variety of methods. Due to its compact size, ETL-8 may be installed in a minivan, yet it is a fully‑featured cable test and fault location system which incorporates burn module and surge wave generator, and is capable of faults pre‑location and cable insulation testing with high DC voltage. FITS INTO COMPACT VEHICLES ETL-8 can fit into most minivans, which is an ideal solution for cable fault location in dense urban areas and on narrow streets. DC TESTING ETL-8 system allows to carry out cable acceptance tests with DC (rectified) high voltage up to 8 kV. FAULT PRE-LOCATION Detachable time-domain reflectometer RIF-9 included with the system is used for determining the distance to faults in electrical power cables with all the main pre‑location methods: Low-voltage method - TDR (time-domain reflectometry): low-resistance faults, open cable breaks, various impedance changes characterization (cable sleeves, branches, etc.), total cable length measurement (incl. on a drum or bundle) and cable shortening ratio measurement. High-voltage methods - ARC/ARC multi-shot (arc reflection method): high-resistance and unstable faults, minimal harmful effects on a cable. - ICE (impulse current envelope method): high-resistance faults that cannot be converted to low-resistance by burning faulty insulation. - DECAY (voltage wave oscillation method): faults with high breakdown voltage. BURN UNIT ETL-8 is supplied with burn unit as standard which delivers current of up to 100 mA at up to 8 kV voltage. Fault conditioning through burning faulty cable insulation is used for converting high-resistance faults to low-resistance so that pre-location and/or pinpointing methods could subsequently be used. SURGE WAVE GENERATOR WITH A SURGE LEVELS SWITCH A surge wave generator with up to 1000 J surge energy is used for pinpointing cable faults with an acoustic method. The generator is supplemented with a surge level switch allowing to select output voltage in the ranges of 0…2 / 0…4 / 0…8 kV, which delivers maximum possible energy of the surge pulses. SAFETY All-round operator safety systems built into ETL-8 includes the following modules and devices: - Overvoltage and overcurrent protection. - Overheating protection. - Equipment and vehicle chassis protective earthing. - Continuous grounding monitoring system. - Emergency stop button. - Automatic discharge device. - Light and sound indication of high voltage. - Vehicle high-voltage compartment door closure sensors. - Safety ON/OFF keylock switch. - Self-health and safety monitoring of high-voltage switches.

特征

供应商代码
ETL-8

同类产品

移动电工实验室ETL-40

供应商代码
107587

价格 按需价格

用于测试绝缘手套 SVS-12Ts 的自动化支架

供应商代码
107574

价格 按需价格

移动式断路器测试系统 UPA 系列

供应商代码
107575

价格 按需价格

用于确定 OLT 油介电强度的自动装置

供应商代码
107714

价格 按需价格

移动电工实验室ETL-10M

供应商代码
107588

价格 按需价格

TANGENS-3M绝缘油介质损耗角正切测量自动装置

供应商代码
107716

价格 按需价格